Electric Water Heater Maintenance

Posted by on Aug 5, 2016 in Electric Water Heater Repair, Water Heater Repair

Electric water heaters are very simple to preserve. A minimum of two times a year, have a look at yours. Use the checklist provided here to cover the basics:

Check out the producer’s plate and record the age and capacity. The day of manufacture is typically found in the first four numbers of the identification number. The capability needs to be listed on the plate. Electric water heaters normally have actually an anticipated life of 10-15 years.Electric Water Heater Maintenance Rapid City

Starting on top and pursuing all-time low, do you see any type of leaks, rust, or corrosion?

Find the cold water supply line and validate a non-leaking shut-off valve.

Validate the cold water supply line goes into the hot water heater at the point classified ‘Cold’.

Situate the warm water supply line exiting at the point marked ‘Hot’. Attempt running warm water at the closest tap and check the temperature level by feeling the pipe.

Confirm the Temperature Pressure Relief Valve is attached to an extension pipe that goes down to within 6 inches of the flooring.

Situate the two panel covers at the front middle and lower locations of the heater. Eliminate both panels, using caution not to touch electric cords, and verify temperature level adjustment. It ought to be in between 120-125 degrees Fahrenheit. More than 130 F rises risk of scalding.

With the panels off, keep in mind the exterior condition of the heating elements. Rusty? These can be quickly changed. Note: you must shut off the electrical power to the unit and drain the storage tank before doing so. Change panels.

Evaluate the drain shutoff at the bottom of the container. Look for dripping. Keep in mind to open up shutoff and drain any kind of debris buildup at the very least once a year. You could require a hose pipe expansion to the floor drain or pipe and pump to the outside. A word of care: never drain more than a gallon while the electric power ferrets out the unit. Never ever turn on unit up until tank contains water. When draining pipes, continue the procedure up until water is clear.

Verify a drain pan is positioned under the tank, especially if on or over the floor of living space. This will enable a forewarning should your container create a leak.

One last note. Remember your electrical water heater is wired in series. This implies if your leading heating element is worn out, you will certainly have no hot water. If the lower element has actually fallen short, you may have cozy water. Always switch off the power to the device when removing or replacing elements.

Do not wait to let us know if you are in need of any type of Rapid City electric water heater repair!